AE MULTIFUNCTIONAL DECARBONIZATION MACHINE TESTING DATA
 
From:Aquarius Energy    Hits:189    11/20/2009 10:44:25 AM

HUAXIN

TEST DATE:OTC 28, 2009   TYPE OF AUTO:MIDIBUS   MILEAGE:65978km   TYPE OF FUEL:DIESEL OIL
 

 

1.TEST SITUATION:hot auto idle speed
 MAXAVEMIN

HC11210398
CO0.130.120.11
CO22.582.512.47
O218.6318.6018.58
2.TEST SITUATION:hot auto idle speed use AE machine for 20 minutes
 MAXAVEMIN
HC787268
CO0.090.080.07
CO21.901.821.73
O218.8718.8518.83
3.TEST SITUATION:hot auto idle speed use AE machine for 40 minutes
 MAXAVEMIN
HC797065
CO0.080.070.07
CO21.821.721.63
O219.0018.9718.96
4.TEST SITUATION:hot auto idle speed use AE machine for 50 minutes
 MAXAVEMIN
HC656057
CO0.070.060.05
CO21.741.661.60
O219.1419.0919.07
5.TEST SITUATION:finish decarbonization
 MAXAVEMIN
HC656257
CO0.090.080.07
CO21.881.791.70
O218.7618.7418.73
 

CHERY

TEST DATE:OTC 14, 2009   TYPE OF AUTO:MINIBUS   MILEAGE:37035km   YEAR:2007   TYPE OF FUEL:GASOLINE
 

 

1.TEST SITUATION:hot auto idle speed
 MAXAVEMIN
HC463623
CO0.040.030.03
CO210.9010.7010.54
O22.232.202.19
2.TEST SITUATION:hot auto idle speed use AE machine for 20 minutes
 MAXAVEMIN
HC352310
CO0.080.040.02
CO212.0511.9311.79
O22.152.112.09
3.TEST SITUATION:hot auto idle speed use AE machine for 40 minutes
 MAXAVEMIN
HC322315
CO0.040.030.03
CO212.9912.8312.65
O22.292.262.24
4.TEST SITUATION:hot auto idle speed use AE machine for 50 minutes
 MAXAVEMIN
HC23157
CO0.050.040.03
CO213.6913.4713.19
O21.551.511.49
5.TEST SITUATION:finish decarbonization
 MAXAVEMIN
HC000
CO0.040.030.02
CO211.3811.2211.08
O21.541.521.51
 

JETTA

TEST DAT:OTC 30, 2009   TYPE OF AUTO:CAR   MILEAGE:122653km   YEAR:2004   TYPE OF FUEL:GASOLINE
 

 

1.TEST SITUATION:hot auto idle speed
 MAXAVEMIN
HC984715
CO0.060.040.03
CO213.2012.7612.40
O22.092.052.03
2.TEST SITUATION:hot auto idle speed use AE machine for 20 minutes
 MAXAVEMIN
HC30100
CO0.080.040.03
CO214.6614.0613.83
O21.941.921.90
3.TEST SITUATION:hot auto idle speed use AE machine for 40 minutes
 MAXAVEMIN
HC1820
CO0.040.020.00
CO211.5311.1710.87
O21.951.921.91
4.TEST SITUATION:hot auto idle speed use AE machine for 50 minutes
 MAXAVEMIN
HC382310
CO0.060.040.02
CO214.1913.8813.59
O21.961.931.92
5.TEST SITUATION:finish decarbonization
 MAXAVEMIN
HC000
CO0.050.020.00
CO214.1713.8113.45
O22.031.981.95
 

NOTE: HC(hydrocarbon) CO(carbon monoxide) CO2(carbon dioxide) O2(oxygen)

 
 
 
 

Aquarius Energy Technology Co.,Ltd.  
Add:706 Crain Hwy, Glen Burnie, MD 21061  Tel:1-301-237-2224 Fax:1-800-838-5927